home > Wilkins 112-600XLHR | Water Pressure Reducing Valve, 75-125 psi > Wilkins 112-600XLHR | Water Pressure Reducing Valve, 75-125 psi
download picture
Wilkins 112-600XLHR | Water Pressure Reducing Valve, 75-125 psiNOTICE: Product images may vary from the actual item due to differences in size or configuration options. The Wilkins 112 600XLHR is a water pressure reducing valve with integral by pass check valve and strainer, designed for residential and commercial potable water systems requiring reliable pressure control and debris protection. Key Specifications: Size: 1 1 2 Inches Pressure Range (HR Option): 75 psi to 125 psi Maximum Working Water Pressure: 300
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

NOTICE: Product images may vary from the actual item due to differences in size or configuration options.

The Wilkins 112-600XLHR is a water pressure reducing valve with integral by-pass check valve and strainer, designed for residential and commercial potable water systems requiring reliable pressure control and debris protection.

 

Key Specifications:

  • Size: 1 1/2 Inches
  • Pressure Range (HR Option): 75 psi to 125 psi
  • Maximum Working Water Pressure: 300 psi
  • Maximum Working Water Temperature: 140°F
  • Notable Certifications: ASSE 1003, IAPMO, CSA, NSF 61

 

Other Related Variants:

  • 1-600XLHR: 1 Inch model size
  • 114-600XLHR: 1 1/4 Inches model size
  • 12-600XLHR: 1/2 Inch model size
  • 2-600XLHR: 2 Inches model size
  • 34-600XLHR: 3/4 Inch model size

 

Materials:

  • Main Valve Body: Low Lead Cast Bronze ASTM B 584
  • Access Covers: Low Lead Cast Bronze ASTM B 584 / Low Lead Brass
  • Fasteners: Stainless Steel, 300 Series
  • Stem & Plunger: Low Lead Cast Bronze ASTM B 584 / Low Lead Brass
  • Elastomers: Buna Nitrile (FDA Approved) / EPDM (FDA Approved)
  • Cap Gaskets: Natural Vulcanized Fibre / Acetal (Delrin™)
  • Strainer Screen: Stainless Steel, 300 Series
  • Seat: Stainless Steel, 300 Series

 

Typical Installation:

Local codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted in accordance with the latest edition of the Uniform Plumbing Code. The Model 600XL may be installed in any position. If installed in a pit, vault or inside application, specify the "SC" sealed cage option. Multiple installations are recommended for wide demand variations or where the desired pressure reduction is more than 4 to 1 (i.e.: 200 psi inlet reduced to 50 psi outlet). Anytime a reducing valve is adjusted, a pressure gauge must be used downstream to verify correct pressure setting. Do not bottom adjustment bolt on bell housing.

 

Standards Compliance:

ASSE Listed 1003; IAPMO Listed; CSA Certified; City of Los Angeles Approved; NSF/ANSI/CAN 61

 

Features & Benefits:

  • Integral By-Pass Check Valve: Prevents buildup of excessive system pressure caused by thermal expansion, protecting water heaters and plumbing systems.
  • Balanced Piston Design: Provides smooth and responsive pressure regulation during flow demand changes while protecting against inlet pressure variations.
  • Integrated Strainer: Built-in 20 mesh stainless steel strainer provides debris protection, suitable for systems requiring frequent cleaning due to sediment.
  • Flexible Installation: Can be installed in any position with various connection options and configurations to meet diverse application requirements.

 

FAQ

 

Q: What is the factory preset pressure for the HR option on the Zurn 112-600XLHR?

A: The Zurn 112-600XLHR with HR option comes factory preset at 85 psi, with an adjustable range of 75 psi to 125 psi. A downstream pressure gauge must be used when adjusting the pressure setting.

Q: Can this valve be installed vertically or horizontally?

A: Yes, the Model 600XL may be installed in any position. For installations in pits, vaults, or indoor applications, the "SC" sealed cage option is recommended for protection.

Q: What pressure reduction ratio is recommended for optimal performance?

A: Multiple installations are recommended for wide demand variations or where the desired pressure reduction exceeds a 4 to 1 ratio (for example: reducing 200 psi inlet to 50 psi outlet).

 

NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.

"Hydrate Everyone, Everywhere!" BottleFillingStations.com | Contact us

Wilkins 112-600XLHR | Water Pressure Reducing Valve, 75-125 psi

Item no : 67085425844
sold recently : Login >>
US$ 737.50
Pay in 4 interest-free payments of $184.38 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 24 - Jun 29

Enjoy 20% off shipping

US$ 737.50

1-11

US$ 663.75

12-35

US$ 516.25

36-59

US$ 442.50

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches