Keep your boat's batteries in peak condition no matter where your adventures take you. The Newmar PT80 stands out as a powerhouse 12V 80-amp charger designed specifically for demanding marine environments. Whether you're running house loads on a live-aboard yacht, powering navigation systems on a workboat, or maintaining deep-cycle batteries on a recreational cruiser, this charger's intelligent design ensures fast, safe recharges that extend battery life and minimize downtime.
Unlike basic chargers that overcharge or underperform, the PT80 employs advanced Phase Three smart technology. It dynamically shifts through bulk, absorption, and float stages, delivering maximum current early on for quick recovery, then tapers precisely to avoid gassing or sulfation. This isn't just charging—it's conditioning your batteries for reliability when you need it most.
Built to withstand salt spray, humidity, and vibrations, the PT80 features a corrosion-resistant stainless steel chassis with polyurethane-coated internals. Its universal input handles 90-264V AC from 50-60Hz sources, making it perfect for global cruising or varying shore power. Switch effortlessly between gel-cell, flooded lead-acid, and AGM batteries via a simple selector—no guesswork required.
Compact yet mighty at 14.8 x 9.6 x 5.6 inches and around 15 pounds, it fits tight bilge spaces without sacrificing power. Plus, it meets stringent safety standards for ignition protection and EMC, giving peace of mind in explosive atmospheres.
Imagine returning from a long day on the water with deeply discharged batteries. The PT80 kicks into bulk mode first, pumping high amps to rapidly replenish capacity—up to 80A without strain. As batteries approach full, it switches to absorption, holding a constant voltage (14.0-14.2V depending on type) to finish filling without excess heat. Finally, float mode maintains trickle current (around 13.4-13.6V) indefinitely, ready for immediate use.
This cycle not only charges faster than single-stage units but prevents common issues like overcharging gel cells or undercharging AGMs. Real-world users report 20-30% longer battery life, translating to fewer replacements and lower costs over seasons.
From sportfishing boats to commercial tugs, the PT80 excels where power demands are high. Pair it with starter and house banks for seamless operation. Its equalize function (on select settings) desulfates flooded batteries periodically, restoring lost capacity. Installation is straightforward: AC input via standard plug, DC outputs to bus bars, and ventilation for cool operation up to 70°C with derating.
| Key Specs | Details |
|---|---|
| Output Voltage | 12V DC |
| Max Charge Current | 80A |
| Input Range | 90-264V AC |
| Battery Banks | Multiple isolated (up to 3) |
| Dimensions (L x W x H) | 14.8" x 9.6" x 5.6" |
| Battery Capacity | 160-800 Ah recommended |
Owners rave about its quiet operation and efficiency, drawing just 12A at 115V full load. It's not just equipment; it's a reliable partner that keeps you powered through storms or sunny sails alike.
It works with gel-cell, flooded lead-acid, and AGM batteries. Use the selector switch to match your setup for optimal voltages.
Yes, it features multiple isolated output banks (up to 3), allowing independent charging without cross-contamination.
It's optional but highly recommended for varying climates. The TCS-12/24 sensor adjusts output voltage automatically for safer, more efficient charging.
Absolutely. It can power DC loads directly without a battery, making it versatile for testing or backup scenarios.
Bulk stage recovers capacity fast, absorption completes the charge precisely, and float maintains readiness without overcharging—extending life by preventing damage common in simpler chargers.
Connect AC input to shore power or generator, DC outputs to battery terminals via fuses, and ensure good airflow. Follow marine wiring standards for safety.
Universal 90-264V AC input works worldwide, from US 115V to European 230V, with power factor correction for efficiency.
80 Amp Phase Three Series Battery ChargerThe "Smart" Charger for Almost Any ApplicationPhase Three "Smart" battery charging technology allows you to select the right size, features and flexibility you require for virtually any application from small recreational craft to large live-aboards, workboats and other commercial vessels. These chargers interact with batteries to put them through the optimum three stage charge process which provides for fastest recovery and ideal conditioning, maximizing battery performance and extending battery life.A selector switch adjusts output voltage to adapt for gel-cell/flooded lead-acid/AGM battery types. An optional temperature compensation sensor also adjusts output for ideal voltage based on changes in the batteries' ambient temperature. All models are housed in a rugged stainless steel case with choice of a natural or durable white powder coated finish, and the internal circuitry is polyurethane coated for maximum corrosion resistance.
Phase Three "Smart" battery charging technology is now available in a wide range of power levels, allowing you to select the right size, features and flexibility you require for virtually any application from small recreational craft to large live-aboards, workboats and other commercial vessels. These chargers interact with batteries to put them through the optimum three stage charge process which provides for fastest recovery and ideal conditioning, maximizing battery performance and extending battery life.
A selector switch adjusts output voltage to adapt for gel-cell/flooded lead-acid/AGM battery types. An optional temperature compensation sensor also adjusts output for ideal voltage based on changes in the batteries' ambient temperature. All models are housed in a rugged stainless steel case with a durable white powder coat finish, and the internal circuitry is polyurethane coated for maximum corrosion resistance.
Features
"Smart" circuitry provides three stage charging?bulk, absorption, float.
Wide model range covers battery system ratings from 14-950 amp-hours
Gel-Cell/Flooded Lead-acid/AGM battery type switch selects optimum charge/float voltages.
Multiple isolated output banks; ammeter indicates total output current. (except PT-7)
Optional sensor adjusts output voltage based on battery temperature. (except PT-7)
Current limiting-prevents damage from overloading.
Charger status clearly displayed with L.E.D. and/or audible indicators or optional remote panel.
Use as a power supply; can power loads without a battery in line.
Built to last?rugged stainless steel case with a durable white powder coat finish with an optional drip shield and marinized internal circuitry.
Numerous Safety and EMC CompliancesTwo year parts and labor warranty
Models
| 12 Volt | 24 Volt | 32 Volt |
| PT-7 | PT-24-8W | PT-32-25W |
| PT-14W | PT-24-13W | |
| PT-25W | PT-24-20U | |
| PT-40U | PT-24-45U | |
| PT-80 | PT-24-60W | |
| PT-24-95U | ||
| Detailed specifications below. | ||
Specifications
| 12 Volt Models | PT-7 | PT-14W | PT-25W | PT-40W | PT-80 |
| Input VAC (50-60 Hz.) | 88-132 or | 85-264 | 90-132 or | 85-135 or | 90-264 |
| Input Amps @ Full Load | |||||
| @ 115 VAC | 2 | 2.8 | 6.5 | 8.5 | 12 |
| @ 230 VAC | 1 | 1.4 | 4 | 4.3 | 7 |
| P.F. Rating | >.65 | .93@230V | .7 | .7 | .95@230V |
| Max Output Amps | 7 | 14 | 25 | 40 | 80 |
| Output Banks | 2 | 3 | 3 | 3 | 3 |
| Battery Capacity (Amp-Hours) | 14-70 | 28-140 | 50-250 | 80-400 | 160-800 |
| Operating Temp. | T-1 | T-2 | T-4 | T-5 | T-7 |
| Case Size Ref. | A-1 | A-2 | A-2 | A-3 | A-5 |
| Weight; Lbs./Kg. | 3.2/1.5 | 8/4 | 8.2/4 | 12/6 | 15.2/7 |
| Optional Temp.Sensor Model | N/A | TCS-12/24 | TCS-12/24 | TCS-12/24 | TCS-12/24 |
| Remote Panel Model | N/A | RP | RP | RP | RP |
| Equalize Option | No | Yes | Yes | Yes | Yes |
| Output Indicator Ref. | M-1 | M-3 | M-3 | M-3 | M-3 |
| Compliance Ref. | CG, CE | CG, CE | CG | CG, CE | CE |
| 24 Volt Models | PT-24-8W | PT-24-13W | PT-24-20U | PT-24-45U | PT-24-60W | PT-24-95U |
| Input VAC (50-60 Hz.) | 85-264 | 90-132 or | 85-135 or | 90-264 | 207-253 | 90-264 |
| Input Amps @ Full Load | ||||||
| @ 115 VAC | 2.8 | 6.5 | 8.5 | 12 | NA | 26 |
| @ 230 VAC | 1.4 | 4 | 4.3 | 7 | 13 | 14 |
| P.F. Rating | .93@230V | .7 | .7 | .95@230V | .7 | .95@230V |
| Max Output Amps | 8 | 13 | 20 | 45 | 60 | 95 |
| Output Banks | 3 | 3 | 3 | 3 | 3 | 3 |
| Battery Capacity (Amp-Hours) | 16-80 | 26-130 | 40-200 | 90-450 | 120-600 | 180-950 |
| Operating Temp. | T-2 | T-3 | T-5 | T-8 | T-6 | T-8 |
| Case Size Ref. | A-2 | A-2 | A-3 | A-5 | A-6 | A-6 |
| Weight; Lbs./Kg. | 8/4 | 8.2/4 | 12/6 | 12.2/6 | 24.1/11 | 24.5/11 |
| Optional Temp.Sensor Model | TCS-12/24 | TCS-12/24 | TCS-12/24 | TCS-12/24 | TP | TCS-12/24 |
| Remote Panel Model | RP | RP | RP | RP | N/A | RP |
| Equalize Option | Yes | Yes | Yes | Yes | No | Yes |
| Output Indicator Ref. | M-3 | M-3 | M-3 | M-3 | M-2 | M-3 |
| Compliance Ref. | CG, CE | CG | CG, CE | EN, CE | EN, CE | EN, CE |
| 32 Volt Model | PT-32-25W |
| Input VAC (50-60 Hz.) | 104-126 |
| Input Amps @ Full Load | |
| @ 115 VAC | 15 |
| @ 230 VAC | N/A |
| P.F. Rating | .7 |
| Max Output Amps | 25 |
| Output Banks | 3 |
| Battery Capacity (Amp-Hours) | 50-250 |
| Operating Temp. | T-6 |
| Case Size Ref. | A-4 |
| Weight; Lbs./Kg. | 12.2/6 |
| Optional Temp.Sensor Model | TP |
| Remote Panel Model | N/A |
| Equalize Option | No |
| Output Indicator Ref. | M-2 |
| Compliance Ref. | EN, CE |
| Inches | Centimeters | |||||
| Ref | H | W | D | H | W | D |
| A-1 | 10.5 | 5.0 | 2.8 | 26.7 | 12.7 | 7.1 |
| A-2 | 12.5 | 7.7 | 4.3 | 31.8 | 19.6 | 10.9 |
| A-3 | 13.85* | 9.5 | 4.8* | 35.2* | 24.1 | 12.2* |
| A-4 | 13.8A | 9.8 | 5A | 35A | 24.9 | 12.7A |
| A-5 | 14.8B | 9.6 | 5.6B | 37.6B | 24.4 | 14.2B |
| A-6 | 17.5C | 12 | 7.2C | 44.5C | 30.5 | 18.3C |
| * Add .75" (1.9 cm) to height and 1.35" (3.4 cm) to depth | ||||||
| T-1 | -10°C to +45°C; Derate linearly from 100% @ 0°C to 80% @ -10°C |
| T-2 | -10°C to +60°C; Derate linearly from 100% @ 40°C to 60% @ 60°C |
| T-3 | -10°C to +60°C; Derate linearly from 100% @ 50°C to 60% @ 60°C |
| T-4 | -10°C to +60°C; Derate linearly from 100% @ 40°C to 60% @ 60°C |
| T-5 | -40°C to +60°C; Derate linearly from 100% @ 50°C to 75% @ 60°C |
| T-6 | -20°C to +50°C; Full output |
| T-7 | -20°C to +70°C; Derate linearly from 100% @ 45°C to 50% @ 70°C |
| T-8 | -20°C to +70°C; Derate linearly from 100% @ 50°C to 50% @ 70°C |
| M-1 | Total output ammeter |
| M-2 | Charge/Float L.E.D. |
| M-3 | Total output ammeter and charger status L.E.D.'s/Alarms |
| | 12 Volt Models | 24 Volt Models | 32 Volt Model | |||
| Charge | Float | Charge | Float | Charge | Float | |
| Setting | @ 50% load | @ .5 amp load | @ 50% load | @ .5 amp load | @ 50% load | @ .5 amp load |
| Gel-Cell | 14.0 VDC | 13.6 VDC | 28.0 VDC | 27.2 VDC | 37.3 VDC | 36.2 VDC |
| Flooded/AGM | 14.2 VDC | 13.4 VDC | 28.4 VDC | 26.8 VDC | 37.8 VDC | 35.7 VDC |